GAS FIRED IGNITERS ACCORDING TO NFPA-STANDARD Heat release max. 10000 kW

  • Compact design with integrated spark transformer and ionisation flame monitor/burner control
  • Built-in flame rod, ideally located
  • No high-voltage cable required on site
  • Guaranteed electromagnetic compatibility
  • Rugged, low-maintenance design
  • Custom outer tube lengths available in 10-mm increments
  • Fuel types include natural gas, conditioned coke oven gas, propane/butane or process gas, according to customer preference and analysis
  • Extremely tight and long pilot flame – no automatic retraction system typically required
  • Class 1, 2 or 3 gas fired igniters according to NFPA also available
  • Also available with flexible outer tube for tilting burners

DOWNLOADS

In Stock

Description

10000 kW NFPA
General data
Outer tube diameter 135 mm
Flame length max. 4500 mm
Outer tube length L 350 – 5000 mm
Gas port Rp 1, top or bottom
Main gas port Rp 2, top
Gas pressure inlet 1 barg
Air port Rp 2, rotatable 4 x 90°
Air pressure operating ≥ 15 mbarg
Power head
Ignition 2 x 5 kV, ignition electrode against ignition electrode
Ambient temperature -30 °C to +60 °C
Protection rating IP 54 or IP 65
Model
with integrated spark transformer and ionisation flame monitor for intermittent operation PA3…
with integrated spark transformer and ionisation flame monitor for continuous operation PDA3…

 